Zone Valve, 24 VAC Reviews

4.8 Rating 137 Reviews
Super easy to remove the dead one and install this one. Just made sure that the wires went back to the same connections - 10 minutes later the heat was back on.
Helpful Report
Posted 7 years ago
I purchased this Taco 555-050RP power head to replace an old one that would no longer actuate the 550 Series zone valve for our first floor heat. Replacement was very easy with only a slight twist needed to pull off the old head and then just removing and reinstalling the three low voltage wires on the terminal strip. The price for these Taco replacement power heads has gone up quite a bit since the last time I purchased one about six years ago and is now more than half the cost of a complete new 550 Series valve, but at least they are still being made in the USA. The price here wasn't exactly cheap, but still less than the other wholesale suppliers I use so, would purchase here again when needed.
Helpful Report
Posted 7 years ago
Easy to install, exact fit replacement for my zone valve. Since I have 4, I'll keep one of these on hand as a ready replacement. The one I replaced was 20 years old.
Helpful Report
Posted 8 years ago
This valve worked as expected, was delivered in a couple of days, and solved my problem. If I would have had to go to a retail outlet, it would have been more expensive and harder to find.
Helpful Report
Posted 8 years ago
Easy fix and easy troubleshoot. I have a 5 zone boiler and in the past 13 years had to swap out two of these valves. They make it easy to buy and the price is good. 9 out of 10 times if your zone is not getting heat it is a bad zone valve. First check the thermostat, turn it up and check the panel to see if the indicator light goes on, if so then manually open the valve by pulling down the zone valve lever, if your line then gets heat you know there isn't a clog in the line so now you know it is a bad valve. Do not pay a plumber, buy the new valve head, you don't need the entire valve, just the head. Turn boiler electric off. Make note where the wires go, usually 3 wires, remove wires from old valve, do a quarter turn, remove old head and install new head, connect wires, turn boiler back on and your heat will work again. When my new boiler was installed the plumber explained to me that these valves go bad and showed me how to replace them. A plumber will charge you $400 for this easy fix.
Helpful Report
Posted 8 years ago
Was able to do the repair by myself. The old unit came off easily and this one twisted right on and I attached the wiring and worked right away.
Helpful Report
Posted 9 years ago
I lost two zones. Heating did not happen. To troubleshoot: Verify power supply is putting out 20-29VAC. Verify valve body opens (pull down the lever on the installed unit. That lever lets hot water through the system, if the valve is operating). If after 10 minutes, the outgoing and incoming pipe are not hot (and you are sure your pipes are not frozen. If frozen is possible, leave lever down for an hour or until you get heat), you have a valve issue, not a head issue. If it is hot on both sides, you are not opening the valve. Push the lever back up. Set your zone thermostat to an insanely hot setting. Use a voltmeter set on Volts AC (~) take the red lead to 1 (top wire screw on head unit) and black to middle wire screw of head unit. You should get somewhere between 20-29VAC. If you don't, it's your power supply or wires to/from thermostat or thermostat. You can ohm out the thermostat and wires by removing the wires from the head. If you do have voltage, your head is bad. My voltage was bad on two units, but once I replaced the one bad unit, the second unit started working (bad unit shunted the voltage, causing zones not to work that had no issue. My understanding, a bad unit could shunt voltage to ground so bad and long, power supply can burn up.
Helpful Report
Posted 9 years ago
This unit head is easy to install as long as you have access to it. Just be sure to lower your thermostat so the heat does not come on. The power to the Power Head has to be OFF before you disconnect the wires. Make sure you replace the wires in exactly the way you removed them. Also, the manual override lever on the Power Head has to be in the up position, like in the diagram, before you remove the Power Head. The job took me about 15 minutes.
Helpful Report
Posted 9 years ago